Residential assessment and inspection at NE of Calgary

Residential assessment and inspection in CalgaryAnother residential assessment and inspection at NE Calgary, Alberta where a utility contractor cut holes in a wooden I-joist incorrectly. AERZ civil structural consulting Inc. prepared a report stating damages to joists and their severity on the floor and house and effect on the future. Necessary structural analysis and assumptions were carried on by AERZ consulting engineer for the previous reasons.

AERZ consulting Inc. also provided structural recommendations for fixing the situation taking into considerations the existing conditions of structural elements, architectural elements and  available utilities close to damaged Nordic I joists.

It is important to use a qualified contractor and consult a structural engineer if needed before having holes cut in beams, rims and joists.

Construction inspection for Steel Building near Okotoks, Alberta

AERZ civil structural consulting Inc. had prepared a construction inspection report for steel building near Okotoks, Alberta. The building is 70 feet long by 40 feet wide by 24 feet eave height.

steel-building near Okotoks Alberta

Also  we prepared drawings for the mezzanine in the building after checking the as built conditions and checking the current mezzanine structure design is safe and satisfy the Alberta building code structurally, CSA steel design standards CSA-S16,  concrete design standards CSA-A23.3, Engineering design in wood standard CSA-O86 and Canadian foundation manual. There were design changes that were not incorporated in the old design drawings.

There was a need to study and check the interaction between the mezzanine and the steel building that was laterally supporting the mezzanine. Therefore a STAAD PRO model was prepared for this previous reason.

steel building and mezzanine

 

Inspection integrity of house after removing of wall by contractor

inspection of house integrity in Sundance area of Calgary Alberta

AERZ consulting Inc. has inspected structural integrity of a house after removal of wall by contractor at Sundance area in Calgary, Alberta. Luckily removal of wall did not affect the house and the wall was not a bearing one. It is important to consult a structural engineer before removal of walls in your house. The contractor installed a beam after removal of wall which will tie the remaining walls and keep the lateral resistance intact. It is important not to engage the beam in carrying the roof loads if wall removed was not a bearing wall. It is expected that roof might deflect under snow loads during winter and causes over-stress in the beam and bearing studs.

Commercial open web steel truss roof safely can carry new air conditioning unit

Commercial open web steel roof trusses and main I beams

3D STAAD PRO model after addition of new make up air conditioning unit of a commercial building in NE of Calgary. The open web steel joists are HSS steel sections with bracing of bottom chords at the middle and end of roof trusses. The roof was safely capable of carrying the new air conditioning unit.

Steel building structural assessment near Calgary city limits

Steel farm building in Foothills Alberta

A previous steel farm building is structurally assessed by AERZ Consulting Inc. using current Alberta building code to change building occupancy and use. The building is 41 ft long by 33 ft wide by 20 ft ridge height. Building and foundations were assessed at the Municipality of Foothills in Alberta; very close to Calgary city limits. The main building steel frames are tapered welded wide flanges while purlins and girts are cold formed Z sections. Dead loads, snow loads, wind and earthquake loads were applied to the building and building elements checked against such loads and there load combinations. The structural analysis and design checks were performed using STAAD PRO software.

Commercial unit roof assessment in SE Calgary

Wooden steel open web truss_commercial unit-SE-Calgary

AERZ civil structural consulting Inc. has done structural assessment of a commercial unit roof at south east Calgary. The owner of the commercial wanted to add a new heavy HVAC unit on top of the roof. The structural assessment found that the roof will not be safe by 25% if the HVAC unit will be installed on the roof (25% over stressed than allowable design values). The roof trusses are wood steel open web trusses with steel tube sections as vertical web members and wooden upper and lower horizontal chords held together by pins. An Engineering solution was provided to owner to support the roof trusses carrying the HVAC unit.

Supporting an open web roof truss of a commercial unit

Roof Open web wood steel truss with pins We have provided a design modification for a roof of a commercial building in south east of Calgary. The roof span consists nearly 50 feet span that is supported by open web wooden steel trusses with pin joints connecting the steel vertical tubes to the wood upper and bottom chords of trusses. The roof is suppose to carry a new heavy high volume air conditioner unit (HVAC) that can not be carried by the old roof trusses.

AERZ Website is currently running smoothly after upgrade

AERZ civil structural consulting Inc. Logo

We are proud to let you know that our website is currently running smoothly after upgrade. We thank our followers for their patience and understanding while the site was not working from May 20th to May 23rd. We regret any missed chance to communicate with our clients but it was a necessary to have a secure website. The blog and the FAQ are new additions to our website. In the next few weeks will have a lot of updates for you. Our Blog will be updated frequently more than our Facebook and LinkedIn pages.

AERZ Consulting Blog




Welcome to our Blog page.

Coming soon will be part of our new website.

Visit us regularly for industry related posts and for activities of AERZ Consulting team.